Prominent & Leading Exporter from Thane, we offer nitrogen concentrator and low volume concentrator -100 sample.

Nitrogen Concentrator

REQUEST CALLBACK

Nitrogen Concentrator
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 2.45 Lakh / PieceGet Latest Price

Product Details:
Country of OriginMade in India
Usage/ApplicationPre-concetration of media
BrandPCI
MaterialSS
ShapeRectangular
CapacityVarious capacity
Temperature RangeAbient to 90 deg
Available Capacity100,150,200 ml
Working Volume80,120,200 ml
Available Braker Size50 x 70,60 x 80,70 x 95 mm

For Hundred samples each of maximum 4 ml volume with timer Microprocessor based water bath with adjustable temperature as well as timer for purging Nitrogen Gas with individually controlled sample concentration and pressure gauge. Model EV-PLUS-100 * Timer Range : 1 sec to 10 hours * Time set up/down arrow keys (15 sec increments) * Temperature Range : Ambient to 90°C * Temperature set up/down keys (1°Increment) * Digital LCD display * Gas Station : 5 Nos. with LED indication * Gas regulator range : 0 to 100 psi (approx.) * Pressure gauge range : 0 to 100 psi * Fully microproprocessor control * Gas line : 5 * S.S Rack 12mm x 75mm Test Tube Standard fittings like Nuts, Ferrules,Union, Couplings, clamps, Hardware etc
Yes! I am interested

Low Volume Concentrator -100 Sample

REQUEST CALLBACK

Low Volume Concentrator -100 Sample
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 40,000 / PieceGet Latest Price

Product Details:
Minimum Order Quantity1 Piece
Usage/ApplicationLED Indication with buzzer
BrandPCI Analytics
MaterialPlastic
Model Name/NumberEV-PLUS-100
ShapeSquare
Capacity11 LTR
Temperature RangeAmbient to 90 C
Featuresit is fully microprocessor controlled and water bath,tempreture,gas station,more advantage.
Automation TypeSemi-Automatic
ColorGrey
Warranty1

Space requirements :Table top or fume hood with minimum dimention L,W& H (cms) 70x60x70 weight capacity 25kg .

work area: flat,level,stable ,surface.

Power supply: 230 AC/samp single phase stable & well grounded.

Gas supply: Laboratory grade nitrogen

Inlet pressure : 60 PSI minimum , 100 psi maximum ( add on/off control valve)

Exhaust : Exhaust duct outlet or fume hood -the exhaust duct must go to outlet the lab.
Yes! I am interested

 
X


Explore More Products

Contact via E-mail
Contact via SMS
Chander (Executive)
PCI Analytics Private Limited
A-71, Road No. 22, Wagle Industrial Estate, Near Spraytech Circle, Thane West
Thane - 400604, Maharashtra, India
Call Us: 
Call Response Rate: 74%
Share Us :
F G T L



Home  |   Profile   |  Products We Offer  |  Site Map  |   Contact Us

© PCI Analytics Private Limited. All Rights Reserved (Terms of Use)
Developed and Managed by IndiaMART InterMESH Limited

PCI Analytics Private Limited